Expert clinical and scientific data review for healthcare and life sciences AI evaluation

Clinical AI evaluation · · 10 min read

How to evaluate AI in urology

Acumen Editorial · Updated November 28, 2026

Urology is a strong fit for AI. Stone disease is common, CT is the standard workup and cystoscopy produces hours of video that a single urologist reads in real time. Vendors and research groups now offer models that find stones, estimate size and flag suspicious bladder lesions. Generative tools draft operative notes and answer patient messages.

The accuracy figures in papers are often high. The question for a health system or a model team is narrower: will this tool hold up on our scanners, our patients and our edge cases, and will our urologists trust it? We answer that with a test plan built around expert grading.

What does AI do in urology today?

Most tools fall into three groups:

  1. Stone imaging. Detect renal and ureteral stones on non-contrast CT, measure size and location, and in some cases estimate composition or volume.
  2. Endoscopy. Mark suspected tumor regions on cystoscopy images or video to support bladder cancer detection.
  3. Documentation and language tasks. Draft operative notes, clinic letters and patient replies, or answer guideline questions for clinicians.

Prostate MRI is its own category with its own reading standards. We cover it separately in our guide to evaluating AI for prostate MRI.

Why do published accuracy numbers overstate readiness?

Two recent studies show the pattern.

A 2026 study in Frontiers in Medicine compared four detection models on 4,000 annotated CT slices from 170 patients at one center. The best fast model reached a recall of 0.92 on the test set. Its sensitivity for stones of 1.5 mm or smaller fell to 64%. The authors noted the drop for very small stones and called for prospective clinical validation.

A 2024 study in the Journal of Clinical Medicine tested cystoscopy software that boxes suspected bladder tumors. Its sensitivity was similar to the urologists' readings. Its specificity was lower, between 0.879 and 0.962 against 0.984 to 0.996 for the urologists. The authors linked the false positives to limited training on normal bladder features such as trabeculation. The model also read saved images, not live video, and the study did not measure whether it made clinicians better.

Neither result means the tools are poor. Both mean a headline number hides the cases that matter: small stones, normal anatomy that looks abnormal and the gap between a still image and a live procedure.

How do you build a urology test set?

Start with your own closed cases, sealed from the vendor and from any tuning. The set should reflect your real case mix, not a clean research sample. Our guide to building representative AI test data covers sampling in more depth.

For stone CT, include:

  • Stones across sizes, with deliberate weight on stones under 3 mm
  • Renal, ureteral and bladder locations
  • Patients with stents, prior surgery or nephrostomy tubes
  • Mimics such as phleboliths and vascular calcifications
  • Low-dose protocols and different scanner vendors

For cystoscopy, include flat lesions, post-treatment inflammation, trabeculated bladders, bleeding and poor-view frames. Add full video clips if the tool claims real-time use.

For documentation tools, sample real encounters across clinic, inpatient and operative settings, with the source record attached so graders can check every statement.

What should urologist graders score?

Score each use case on its own terms. One overall accuracy figure across stone, endoscopy and text tasks tells you little.

Use caseWhat to scoreWho gradesFailure to watch
Stone CT detectionSensitivity by size and location, false positives per studyUrologist and body radiologistMissed small ureteral stones, calcifications called stones
Stone sizingAgreement with expert measurement, error in mmRadiologistErrors that change the treatment decision
Cystoscopy lesion detectionSensitivity, specificity, overlap with expert-marked regionsUrologist with cystoscopy volumeFalse alarms on normal mucosa, missed flat lesions
Operative and clinic notesFactual accuracy, omissions, correct lateralityUrologistWrong side, invented findings
Patient messagesSafety, correct escalation, clarityUrologist and nurseMissed red flags such as fever with obstruction

Sizing deserves its own line. A stone measured at 4 mm instead of 7 mm can push a patient toward watchful waiting when a procedure was the right call. Graders should flag errors that would change management, not just record the millimeters.

How many graders do you need, and how do you handle disagreement?

Use at least two independent graders per case and a senior urologist to adjudicate. Record each grader's specialty and years in practice. Measure agreement before you measure the model: if two urologists disagree on a case, the model's answer on that case is not a clean pass or fail. Our piece on inter-rater reliability in medical AI explains how to report it.

Write the rubric before grading starts. For detection tasks, define what counts as a hit, how close a bounding box must be and how to score multiple stones in one study. For text tasks, define the error categories and which ones are severe.

What should you ask vendors before testing?

Ask for the training and validation data in plain terms: how many sites, which scanners, which countries and what share of small stones or flat lesions. Ask whether any of your own cases could have been in the training data. Ask who labeled the reference standard and whether they were urologists or general annotators. Ask what the tool does when it is unsure, and whether it can say so. Ask for regulatory status per use case, since a cleared detection feature does not cover a new sizing or composition feature. The answers tell you which edge cases to weight in your own test set.

How do you measure value in practice?

Accuracy on a test set is the entry ticket. After a passing result, run a short prospective pilot and track:

  • Read time per stone CT with and without the tool
  • How often urologists accept, edit or reject the output
  • Changes in missed findings found on later review
  • False alarm burden per cystoscopy session
  • Note edit time and the share of notes signed without changes

Rerun the sealed test set after every model update. A version that improves on large stones can get worse on small ones.

Evaluation checklist

  • Use cases defined separately: stone CT, sizing, cystoscopy, documentation
  • Sealed test set from your own cases, held back from the vendor
  • Small stones, mimics, stents and post-surgical cases included
  • Normal and inflamed bladder frames included for cystoscopy
  • Two independent graders per case, senior adjudicator, agreement reported
  • Rubric written before grading
  • Results reported by stone size, location and lesion type
  • Prospective pilot with acceptance and edit rates
  • Rerun plan for every model update

How Acumen helps

We supply credentialed urologists, radiologists and nurses to build urology test sets, write rubrics and grade AI outputs, with two-reviewer adjudication on every item. Each grade carries the reviewer's specialty and the agreement record, so the result holds up with clinical leadership and procurement. It is part of our medical model evaluation work.

Request a sample dataset

For related guides, read how to evaluate AI in nephrology, how to evaluate AI radiology report generation and how to build a golden dataset for medical AI.

FAQ

How is AI used in urology?

AI in urology mainly detects and measures kidney and ureteral stones on CT, flags suspected bladder tumors on cystoscopy images and drafts documentation such as operative notes and patient replies. Prostate MRI tools form a separate category. Each use case needs its own test set and expert graders, because the failure modes differ.

How accurate is AI for kidney stone detection on CT?

Published models often report recall above 0.90, but performance drops on small stones. A 2026 Frontiers in Medicine study found sensitivity of 64% for stones of 1.5 mm or smaller, using single-center data. Test any tool on your own scans, with results broken out by stone size and location.

Can AI detect bladder cancer during cystoscopy?

Research systems can mark suspected tumor regions on cystoscopy images with sensitivity close to urologists. A 2024 Journal of Clinical Medicine study found lower specificity than urologists and tested saved images rather than live video. Check real-time performance and false alarms on normal bladder tissue before relying on it.

Who should grade urology AI outputs?

Practicing urologists with relevant case volume, plus body radiologists for CT tasks and nurses for patient messaging. Use two independent graders per case and a senior urologist to adjudicate. Record each grader's specialty and experience so the evaluation can be defended to clinical leadership and buyers.

What should a urology AI test set include?

Your own closed cases, sealed from the vendor. Include small stones, ureteral and bladder stones, stents, prior surgery, phleboliths and low-dose scans for CT. For cystoscopy include flat lesions, inflammation, trabeculation and poor-view frames. For documentation, attach the source record so graders can check every statement.

How often should urology AI be re-evaluated?

Rerun the sealed test set after every model or software update and at a fixed interval, such as each quarter. Compare results by stone size and lesion type, not just overall accuracy. Track acceptance and edit rates in live use, since a drop often shows drift before formal testing does.

From the Acumen archive. Explore expert data and Healthcare & Pharma.

← Back to Insights