Nuclear medicine physicians and medical physicists evaluating PET and SPECT AI tools on clinical tasks, scanners and tracers

Healthcare · · 8 min read

How to evaluate AI in nuclear medicine

Acumen Editorial · Updated November 27, 2026

Nuclear medicine AI has moved from research to product. In January 2026, Diagnostic Imaging reported FDA 510(k) clearance for GE HealthCare's MIM LesionID Pro, which segments whole-body PSMA uptake on PET/CT and SPECT/CT to help physicians assess tumor burden. In February, Xtalks reported clearance for Spectrum Dynamics Medical's Veritas.AI, a deep learning noise reduction platform for its SPECT/CT system. The company reports scan time reductions of up to 50%.

The FDA had authorized 1,451 AI-enabled devices by the end of 2025, per a MedTech Dive release. Clearance tells you a tool met its submitted claim. It does not tell you how it performs on your tracers, your protocols and your patients. That is the job of a local evaluation.

Where is AI used in nuclear medicine?

  • Reconstruction and denoising. Models clean up low-count images so sites can shorten scans or lower dose.
  • Segmentation and quantification. Tools outline lesions and organs and compute SUV, metabolic tumor volume or total tumor burden.
  • Detection and classification. Models flag suspicious uptake on PSMA, FDG or bone scans.
  • Theranostics and dosimetry. Software estimates absorbed dose and tracks response across therapy cycles.
  • Reporting support. Generative tools draft impressions from findings. Our guide to evaluating AI radiology report generation covers that layer.

Each category fails differently, so each needs its own test.

Why is a better-looking image not enough?

A denoised scan can look cleaner and still hide a small lesion or shift an SUV. The Society of Nuclear Medicine and Molecular Imaging AI Task Force made this point in its RELAINCE guidelines, published in the Journal of Nuclear Medicine in 2022. The authors state that "AI algorithms should be evaluated on clinical tasks."

RELAINCE asks each evaluation to state a claim: the task, the patient population, the imaging process, how the answer is read out and the figure of merit against a reference standard. It separates four classes of evidence: proof of concept, technical task-specific, clinical and post-deployment. It warns that clinical claims "should not be put forth based on POC evaluation."

For a buyer, that means one question first. What decision does this tool change, and how will we measure it?

How do you build a nuclear medicine test set?

Start from your case mix, not the vendor's. A PSMA PET tool trained mostly on one tracer and one scanner generation may behave differently on another. Low-count studies, delayed post-therapy scans and pediatric exams are exactly where denoising is sold, and exactly where errors hide.

Include:

  • Each tracer you use, with the uptake patterns that confuse readers, such as physiologic uptake and inflammation.
  • Each scanner and protocol, including older systems and reduced-dose acquisitions.
  • Small and low-contrast lesions, where denoising and segmentation fail first.
  • Prior studies, so tools that track change over time are tested on change.
  • Cases from outside the training sites. RELAINCE notes that external test data from multiple institutions improves confidence in generalizability.

Keep the test set private and separate from any data used to tune the tool. Our guide to building representative AI test data covers sampling in more depth.

Who should grade nuclear medicine AI?

Nuclear medicine physicians and dual-boarded radiologists set the reference standard for reads. Medical physicists check quantification, reconstruction and dosimetry. Technologists can judge whether a protocol change is realistic in a busy department. For theranostics, include the treating oncologist, because response calls drive the next cycle. Our guide to evaluating oncology AI decision support covers that handoff.

Two independent readers per case, with adjudication, give you a reference you can defend. Report agreement before you report model accuracy. If two experts disagree on 20% of lesions, a model cannot be measured more precisely than that. Our piece on inter-rater reliability in medical AI explains how to report it.

What should you measure?

Tool typePrimary measureFailure to look forWho grades
Denoising or fast reconstructionLesion detectability versus full-count referenceSmall lesions smoothed away; SUV shiftNuclear medicine physicians, physicists
Segmentation and tumor burdenVolume and SUV agreement with expert contoursPhysiologic uptake counted as diseaseNuclear medicine physicians
Detection and classificationLesion-level sensitivity and false positives per scanMisses in bone, nodes or low-uptake diseaseTwo readers plus adjudication
DosimetryAbsorbed dose error against a reference methodBias in small organs or lesionsMedical physicists
Report draftingClinically significant errors per reportWrong lesion count or lateralityNuclear medicine physicians

Report confidence intervals, as RELAINCE recommends, and break results down by tracer, scanner, lesion size and patient group. An average hides the subgroup where the tool breaks.

How do theranostics change the evaluation?

Theranostic programs pair a diagnostic scan with a radioligand therapy that targets the same receptor. AI touches every step: patient selection on the baseline scan, dosimetry after each cycle and response assessment on follow-up. An error at selection changes who gets treated. An error in dosimetry changes how much radiation an organ receives.

That raises the bar. Test selection tools against the eligibility calls of experienced readers, not just lesion counts. Test dosimetry against an established reference method, with physicists reviewing organ and lesion estimates. Test response tools on paired baseline and follow-up studies, where the question is change, not presence. Keep each cycle's images linked to the same patient so graders see the whole course of treatment, as they would in clinic.

How do you keep evaluating after go-live?

Software changes. Scanners are replaced. New tracers arrive. RELAINCE recommends post-deployment monitoring, including phantom checks after software updates and watching for data drift. The FDA's December 2024 final guidance on predetermined change control plans governs how cleared AI can be updated, so ask vendors what their plan allows and how you will be told.

Keep a fixed regression set and rerun it after every update. Regulators are also thinking about human-style evaluation. Radiology Business reported in October 2026 that Rick Abramson, MD, director of the FDA's Digital Health Center of Excellence, believes generative AI should be evaluated like human physicians. Our guide to clinical AI model monitoring covers the operating model.

Checklist: before you sign

  • The vendor states the clinical task and claim in writing.
  • Test cases come from your tracers, scanners and protocols.
  • Two nuclear medicine physicians grade each case, with adjudication.
  • Physicists check quantitative bias on phantoms and patients.
  • Results are reported by lesion size, tracer and scanner.
  • A regression set is rerun after every software update.

How Acumen helps

Acumen builds medical model evaluation sets graded by credential-verified specialists. For nuclear medicine, we match nuclear medicine physicians, radiologists and medical physicists to your task, write rubrics with your team, grade with independent second readers and report agreement on every batch. You get a reference standard you can defend and rerun.

Request a sample dataset

For related reading, see our guides to evaluating AI radiology report generation, inter-rater reliability in medical AI and clinical AI model monitoring.

FAQ

How is AI used in nuclear medicine?

AI in nuclear medicine is used to denoise and reconstruct low-count PET and SPECT images, segment lesions and organs, compute SUV and tumor burden, flag suspicious uptake, estimate dosimetry for theranostics and draft reports. Each use fails differently, so each needs its own evaluation on a defined clinical task, with expert readers setting the reference standard.

What are the RELAINCE guidelines?

RELAINCE is a set of best practices for evaluating AI in nuclear medicine, published by the SNMMI AI Task Force in the Journal of Nuclear Medicine in 2022. It asks for a stated claim for each evaluation, separates proof-of-concept, technical, clinical and post-deployment evidence, and recommends testing on clinical tasks with unseen data and confidence intervals.

Is FDA clearance enough to trust a PET or SPECT AI tool?

No. Clearance shows the tool met its submitted claim on the vendor's data. Your tracers, scanners, protocols and patients may differ. Run a local evaluation on private cases from your own department, graded by nuclear medicine physicians, before the tool affects reads, and rerun it after every software update.

How do you validate AI denoising for PET or SPECT?

Compare denoised or shortened scans with full-count reference scans of the same patients or phantoms. Measure lesion detectability and quantitative bias in SUV, not just visual quality. Include small and low-contrast lesions, pediatric and post-therapy studies. Have nuclear medicine physicians read both versions blind, and have physicists check quantification.

Who should grade nuclear medicine AI outputs?

Nuclear medicine physicians or dual-boarded radiologists should set the reference for reads. Medical physicists should check reconstruction, quantification and dosimetry. Treating oncologists should review theranostic response calls. Use two independent readers per case with adjudication, and report their agreement before reporting model accuracy.

Can Acumen build a nuclear medicine evaluation set?

Yes. We match credential-verified nuclear medicine physicians, radiologists and medical physicists to your tracers and tasks. We write rubrics with your team, grade each case with independent second readers, report agreement per batch and keep a per-item record of who graded what. Start with a sample dataset on your own cases.