Cytopathologists and cytotechnologists evaluating cytology AI outputs

Healthcare AI evaluation · · 9 min read

How to evaluate AI in cytology

Acumen Editorial · Updated November 28, 2026

Cytology is where AI meets population screening. A single slide can hold tens of thousands of cells, and only a few may matter, as Ireland's National Cervical Screening Laboratory put it when it opened a feasibility study of AI-supported digital review in May 2026. That ratio is why vendors are pushing in, and why evaluation has to be stricter than a demo.

We work with cytopathologists and cytotechnologists who grade these systems. Here is what we ask them to check.

Where is AI in cytology being used today?

Three use cases come up most often.

  • Cervical screening. Hologic's Genius Digital Diagnostics System received FDA clearance in early 2024. It images Pap slides and uses AI to identify the cells cytologists and pathologists should review (MedTech Dive). Hologic cites a 28% reduction in false negatives for HSIL and worse lesions compared with microscope review. That is a company figure, so treat it as a claim to test.
  • HPV-positive triage. In September 2026, NEJM AI published an independent external validation of an AI model for p16/Ki-67 dual-stain triage. It was tested on 9,006 slides from four National Cancer Institute-managed cohorts, with a separate NCI team holding the biopsy results.
  • Thyroid FNA and urine cytology. Research systems map slides to the Bethesda System for thyroid cytology and the Paris System for urine. The hard part is the indeterminate middle, not the clear benign and malignant ends.

What should ground truth be for cytology AI?

A cytology call is an interpretation. The truth is what happened to the patient.

The NEJM AI dual-stain study is a good model. It used biopsy-confirmed precancer as the reference for the AI, manual dual-stain reading and Pap cytology alike. The team that held outcomes ran the analysis. That separation is what makes the result believable.

For your own evaluation:

  1. Use histology or follow-up as the reference wherever it exists. Use expert consensus only where it does not, and say so.
  2. Keep the reference team separate from the team tuning the model.
  3. Label at two levels. Cell- or region-level labels help you see what the model looks at. Slide- and patient-level outcomes decide whether it is safe.
  4. Record who labeled what. Credential, years in practice and lab. Panels with mixed backgrounds catch more edge cases.

Our guide to building a golden dataset for medical AI covers the mechanics of reference sets in more depth.

How do you score sensitivity and specificity without fooling yourself?

Report both, at a threshold you fixed in advance. The NEJM AI paper shows why.

In the final locked cohort, the AI reached 88% sensitivity versus 78% for manual dual-stain reading. Specificity went the other way: 54% for the AI versus 63% for manual reading. A specificity-oriented setting, defined before testing, reached 62% specificity at 86% sensitivity.

Note also that the AI and manual readers were scored against the same biopsy outcomes. That is the only fair comparison. If the reference had been another manual read, the AI would have been graded on agreement with a human, not on finding disease.

Neither number tells the whole story alone. Higher sensitivity in screening means fewer missed precancers. Lower specificity means more colposcopy referrals. The right trade depends on the program, and the program's clinicians should pick it before they see the test results.

What to measureWhy it matters in cytologyWho should judge it
Patient-level sensitivity for CIN2+ / high-grade lesionsMissed disease is the main safety riskCytopathologist with histology access
Specificity and referral rateDrives colposcopy volume and costScreening program lead
Performance in indeterminate categories (ASC-US, AUS, atypical urothelial cells)Where readers disagree most and AI adds most riskPanel of 3+ cytopathologists
Results by preparation type and scannerSystems often need separate models per prepLab director
Unreadable or inadequate slide rateSilent failures shift workload back to humansCytotechnologist
Reader performance with and without AIThe real deployment is human plus AIReader study design team

Why do the indeterminate categories need their own report?

Because averages hide them. Most slides in a screening population are clearly normal. A model can post a strong overall accuracy while doing poorly on the small, ambiguous group where decisions are hardest.

The NEJM AI authors noted that an earlier version of the system was less reliable on borderline cells. That is typical. Ask vendors for results split by category, and build your own test set with enough indeterminate cases to give a stable estimate. In thyroid FNA, that means enough atypia of undetermined significance and follicular neoplasm cases to measure, not a handful.

When readers disagree, measure that disagreement before you blame the model. Our piece on inter-rater reliability in medical AI explains how to set a realistic ceiling.

Should you run a reader study before deployment?

Yes. In cytology, AI almost always works as a triage or assist tool. The question is whether cytologists using it do better than cytologists without it.

A useful reader study:

  • Uses the same slides, read with and without AI support, with a washout period between reads.
  • Includes cytotechnologists and cytopathologists, since both touch the workflow.
  • Tracks time per slide and changes of mind, not just final accuracy.
  • Watches for automation bias: readers accepting an AI flag they would have questioned on glass.

Ireland's NCSL study is structured along these lines. It assesses accuracy and safety, staff support and efficiency, and keeps all clinical decisions with medical scientists and cytopathologists.

Retrospective validation checklist

Before a cytology AI system touches a live program, confirm:

  • Reference standard is histology or follow-up, held by an independent team
  • Operating threshold locked before the test set was opened
  • Test set comes from a different site, scanner or time period than training data
  • Results reported by category, including every indeterminate class
  • Results reported by preparation type (ThinPrep, SurePath, conventional) and scanner
  • Inadequate and unreadable slide rate reported
  • Reader study with and without AI completed
  • Plan for prospective monitoring after go-live, since retrospective results do not show whether referrals change

The dual-stain authors were explicit on that last point. Their design was retrospective, and they called for prospective interventional studies before drawing conclusions about clinical impact.

How Acumen helps

We supply credential-verified cytopathologists and cytotechnologists to build and grade cytology evaluation sets. That includes cell- and slide-level annotation, adjudication panels for indeterminate categories, reader-study design and documentation of who labeled each item. See our medical data annotation service and our medical model evaluation work.

Request a sample dataset

For related reading, see how we approach evaluating AI in pathology, evaluating AI in dermatopathology and inter-rater reliability in medical AI.

FAQ

How accurate is AI in cytology?

It depends on the task and threshold. In a September 2026 NEJM AI validation of dual-stain triage, the AI reached 88% sensitivity versus 78% for manual reading in the final cohort, but lower specificity, 54% versus 63%. Accuracy should always be reported as a sensitivity and specificity pair against biopsy-confirmed outcomes.

What is the right ground truth for cytology AI?

Histology or clinical follow-up wherever it exists. A cytologist's read is an interpretation, so using one reader as truth caps the evaluation at that reader's accuracy. Where outcomes are missing, use an adjudicated panel of three or more cytopathologists and state that limitation in the report.

Is AI in cervical cytology FDA cleared?

Yes. Hologic announced FDA clearance of its Genius Digital Diagnostics System in early 2024. It digitizes Pap slides and uses AI to identify cells for cytologists and pathologists to review. Clearance covers the cleared use; your lab still needs local validation on its own population, preparation and workflow.

Why do indeterminate categories matter so much?

They are where human readers disagree most and where errors change management. A model can score well overall because most screening slides are normal while doing poorly on ASC-US, AUS or atypical urothelial cells. Ask for category-level results and include enough indeterminate cases in your test set to measure them.

Do we need a reader study, or is standalone accuracy enough?

You need a reader study. Cytology AI is deployed as an assist or triage tool, so the real question is whether cytologists with AI outperform cytologists without it. Measure accuracy, time per slide, changes of mind and signs of automation bias, using the same slides read with and without support.

Who should label and grade a cytology evaluation set?

Credentialed cytopathologists and cytotechnologists, matched to the specimen type. Cervical, thyroid and urine cytology each have their own reporting systems and pitfalls. Record each labeler's credential and lab, and use multi-reader adjudication for borderline cases so every label can be defended in review.

From the Acumen archive. Explore expert data and Healthcare & Pharma.

← Back to Insights