Expert clinical and scientific data review for healthcare and life sciences AI evaluation

Life sciences AI evaluation · · 10 min read

AI in chromatography: how to evaluate it before it integrates your peaks

Acumen Editorial · Updated November 28, 2026

Chromatography is the workhorse of the regulated lab. Bob McDowall, writing in Technology Networks, puts it at 40 to 100 percent of the workload in regulated laboratories. That makes it the obvious place to apply machine learning. It also makes it the place where a bad model does the most damage. A wrong baseline is not a cosmetic error. It can turn a failing impurity result into a passing one.

Vendors and large pharma teams are now shipping real tools. Analytical development, QC and QA teams need a way to prove those tools work on their methods, their columns and their sample matrices before anyone relies on them.

What does AI do in chromatography today?

Most applications fall into four groups. The HPLC 2026 program in Indianapolis gives a fair snapshot. Amgen presented in silico chromatography modeling for retention-time-aligned method development. Waters presented an ensemble machine learning approach to custom peak integration. Merck described an AI-enabled digital twin of the LC system for screening, optimization and lifecycle monitoring.

FunctionWhat the AI doesWho should grade itGround truth
Retention predictionPredicts retention times across columns, gradients and temperaturesMethod development chemistsMeasured retention on your systems
Method developmentScreens and optimizes conditions to maximize resolutionSenior analytical scientistsMethods your team developed and validated
Peak detection and integrationFinds peaks, places baselines, splits overlapping peaksExperienced QC analysts and reviewersExpert-integrated chromatograms
Trending and monitoringFlags drift in system suitability and column performanceQC leads and QAHistorical investigations and OOS records

An LCGC International article from September 2025 named peak integration, peak selection and report generation as the near-term targets. It described data acquisition as too risky for AI for now. We agree with that order. Start where an expert can check every output.

Why is peak integration the hardest part to evaluate?

Because experts disagree, and regulators watch closely. Conventional algorithms find peaks from first and second derivatives. LCGC notes they struggle with retention drift, matrix effects and compressed or stretched peaks. Machine learning promises to handle those cases. But "correct" integration of a shoulder or a rising baseline is a judgment call.

The compliance history is long. McDowall lists failure to control chromatographic integration among the most common chromatography data system violations in FDA warning letters. He says inspectors now ask whether chromatograms are being "integrated into compliance." His guidance is specific: save the processing method, record every reintegration in the audit trail, and integrate standards and samples consistently.

Any AI integrator inherits those rules. If it reintegrates a run, the change has to be visible, attributable and justified. If a vendor cannot show you that trail, stop there.

How should you build a chromatography evaluation set?

Build it from your own data, not the vendor's demo. We use five rules.

  1. Sample real methods. Pull chromatograms from the assays and impurity methods you run most, plus the ones that cause the most reintegration.
  2. Over-sample the hard cases. Include co-eluting peaks, shoulders, tailing, drifting baselines, low-level impurities near the reporting threshold and matrix interference.
  3. Get independent expert integrations. Have two or more experienced analysts integrate each chromatogram blind to each other and to the AI. Adjudicate disagreements with a senior reviewer and record why.
  4. Keep the test set separate. Never let the vendor tune on the chromatograms you score them on. LCGC's McDowall and Lotfinia note that AI teams use "validation" to mean tuning data, which is not what GMP means by the word.
  5. Tag every item. Record method, column, instrument, analyte, concentration range and difficulty so you can report results by slice.

What should you measure?

Measure agreement where it changes a reported result. Average peak-area agreement across clean main peaks will look excellent and tell you nothing.

  • Peak detection: missed and false peaks, reported separately for impurities near the reporting threshold.
  • Integration: percent difference in area and height against the adjudicated expert integration, per peak type.
  • Result impact: how often AI integration changes a pass or fail call, or the reported impurity profile.
  • Automation rate: the share of runs integrated with no manual intervention. McDowall and Lotfinia suggest setting a metric such as automatic integration above 90 percent during method development.
  • Retention and method predictions: error in predicted retention time and resolution, checked on real runs on your instruments.
  • Consistency: identical treatment of standards and samples in the same sequence.

Which regulatory expectations apply?

Treat any AI that touches GMP chromatography data as a computerized system that needs validation for its intended use. Our guide to GxP AI validation covers the general approach. Three points matter most here.

First, data integrity rules do not change because a model made the change. Audit trails stay on and every reintegration stays attributable. Second, the draft EU GMP Annex 22 leans hard toward static, deterministic models. McDowall and Lotfinia read it as discouraging generative AI, large language models and probabilistic outputs in critical GMP uses. Third, models change. Plan how you will requalify after a vendor update, as we describe in AI model change control for pharma.

Where do AI chromatography claims usually break?

They break on data quality first. As McDowall and Lotfinia put it, "no amount of AI input can resurrect poor chromatography." A model that integrates a badly resolved separation well is still integrating a badly resolved separation.

They break on transfer second. A model trained on one vendor's instruments, one column chemistry or one lab's habits may drift on another. Amgen's HPLC 2026 talk named method transfer across systems and labs as the goal, which tells you it is still the hard part.

They break on accountability third. LCGC's September 2025 article was clear that analysts should verify AI results and remain responsible for what they report. That has to show up in your SOPs, not just the vendor's slides. For the wider QC picture, see our piece on AI in pharmaceutical quality control.

A pre-purchase checklist

  • The vendor scored the tool on your chromatograms, not theirs.
  • Expert integrations were blind, independent and adjudicated.
  • Results are reported per method, peak type and difficulty slice.
  • Missed impurities near the reporting threshold are reported separately.
  • Every AI reintegration writes to the audit trail with a reason.
  • Integration parameters for standards and samples are identical.
  • A requalification plan exists for model and software updates.
  • An analyst signs off every reported result.

How Acumen helps

We build the expert ground truth that makes these tests meaningful. Acumen recruits experienced analytical chemists and QC reviewers by technique and method type. They integrate chromatograms independently, adjudicate disagreements and document the reasoning behind each baseline. We deliver evaluation sets tagged by method, column, analyte and difficulty, with reviewer agreement for every item. See our life sciences model evaluation service, or how we validate data and models for regulated teams.

Request a sample dataset

For related reading, see our guides to AI in mass spectrometry, AI in metabolomics and AI in proteomics.

FAQ

How is AI used in chromatography?

AI in chromatography predicts retention times, screens and optimizes HPLC method conditions, detects and integrates peaks, and trends system suitability data. At HPLC 2026, Amgen, Waters and Merck presented work on in silico method development, machine learning peak integration and LC digital twins. Most regulated labs start with integration and reporting, where experts can check every output.

Can AI integrate HPLC peaks reliably?

It can on well-resolved peaks, and machine learning may handle drifting baselines and overlapping peaks better than derivative-based algorithms. Reliability has to be proven on your own methods against expert integrations. Report missed impurities and pass or fail changes separately, because average peak-area agreement on clean main peaks hides the errors that matter.

How do you validate AI peak integration?

Build a test set from your own chromatograms, have two or more experienced analysts integrate each one blind, adjudicate disagreements and score the AI against that reference. Keep the test set away from vendor tuning. Validate the system for its intended use, keep audit trails on, and plan requalification for every model update.

Does AI peak integration create data integrity risk?

It can. Integration control is a frequent finding in FDA warning letters about chromatography data systems. An AI integrator must save its processing method, log every reintegration in the audit trail with a reason, and treat standards and samples the same way. An analyst stays responsible for every reported result.

Does EU GMP Annex 22 allow AI in chromatography?

The draft Annex 22 covers AI in critical GMP applications and favors static, deterministic models with defined acceptance criteria. LCGC International commentators read it as discouraging generative AI, large language models and probabilistic outputs in those uses. It was still a draft in late 2026, so check the final text before you commit.

Who should evaluate AI for chromatography?

Experienced analytical chemists should judge method development and retention predictions. Senior QC analysts and data reviewers should produce and adjudicate reference integrations. QA should review audit trails and change control. Record each reviewer's technique experience and how disagreements were resolved, so the evaluation holds up in an inspection.

From the Acumen archive. Explore expert data and Healthcare & Pharma.

← Back to Insights